Ars Cov Rna Test

Lab Reagents

Human IgG antibody Laboratories manufactures the ars cov rna test reagents distributed by Genprice. The Ars Cov Rna Test reagent is RUO (Research Use Only) to test human serum or cell culture lab samples. To purchase these products, for the MSDS, Data Sheet, protocol, storage conditions/temperature or for the concentration, please contact SARS Test. Other Ars products are available in stock. Specificity: Ars Category: Cov Group: Rna Test

Rna Test information

5E PINK RNA Lysis Kit 100

PINK5E100-RNA 100pack
EUR 380
Description: Bead lysis kits for the homogenization of small, soft or medium-tough samples. Pack of 100, 5mL Eppendorf Safe-Lock tubes prefilled with stabilized ceramic beads. RNase free.

5E PINK RNA Lysis Kit 20

PINK5E20-RNA 20pack
EUR 136
Description: Bead lysis kits for the homogenization of small, soft or medium-tough samples. Pack of 20, 5mL Eppendorf Safe-Lock tubes prefilled with stabilized ceramic beads. RNase free.

Pink RINO RNA Lysis Kit 50

PINKR1-RNA 50pack
EUR 181
Description: Bead lysis kits for the homogenization of small, soft or medium-tough samples. Pack of 50, 1.5mL RINO screw-cap tubes prefilled with stabilized ceramic beads. RNase free.

Pink RINO RNA Lysis Kit 250

PINKR5-RNA 250pack
EUR 576
Description: Bead lysis kits for the homogenization of small, soft or medium-tough samples. Pack of 250, 1.5mL RINO screw-cap tubes prefilled with stabilized ceramic beads. RNase free.

Navy RINO RNA Lysis Kit 250

NAVYR5-RNA 250pack
EUR 666
Description: Bead lysis kits for the homogenization of large, tough samples. Pack of 250, 1.5mL RINO screw-cap tubes prefilled with stainless steel beads. RNase free.

5E Navy RNA Lysis Kit 100

NAVY5E100-RNA 100pack
EUR 453
Description: Bead lysis kits for the homogenization of large, tough samples. Pack of 100, 5mL Eppendorf Safe-Lock tubes prefilled with stainless steel beads. RNase free.

5E Navy RNA Lysis Kit 20

NAVY5E20-RNA 20pack
EUR 153
Description: Bead lysis kits for the homogenization of large, tough samples. Pack of 20, 5mL Eppendorf Safe-Lock tubes prefilled with stainless steel beads. RNase free.

Navy RINO RNA Lysis Kit 50

NAVYR1-RNA 50pack
EUR 202
Description: Bead lysis kits for the homogenization of large, tough samples. Pack of 50, 1.5mL RINO screw-cap tubes prefilled with stainless steel beads. RNase free.

5E RED RNA Lysis Kit 100

RED5E100-RNA 100pack
EUR 429
Description: Bead lysis kits for the homogenization of large, soft or medium-tough samples. Pack of 100, 5mL Eppendorf Safe-Lock tubes prefilled with stabilized ceramic beads. RNase free.

5E RED RNA Lysis Kit 20

RED5E20-RNA 20pack
EUR 148
Description: Bead lysis kits for the homogenization of large, soft or medium-tough samples. Pack of 20, 5mL Eppendorf Safe-Lock tubes prefilled with stabilized ceramic beads. RNase free.

Red RINO RNA Lysis Kit 50

REDR1-RNA 50pack
EUR 195
Description: Bead lysis kits for the homogenization of large, soft or medium-tough samples. Pack of 50, 1.5mL RINO screw-cap tubes prefilled with stabilized ceramic beads. RNase free.

Red RINO RNA Lysis Kit 250

REDR5-RNA 250pack
EUR 638
Description: Bead lysis kits for the homogenization of large, soft or medium-tough samples. Pack of 250, 1.5mL RINO screw-cap tubes prefilled with stabilized ceramic beads. RNase free.

YELLOW RINO RNA Lysis Kit 50

YELLOWR1-RNA 50pack
EUR 199
Description: Bead lysis kits for the homogenization of small cell suspensions (ex - E. coli). Pack of 50, 1.5mL RINO screw-cap tubes prefilled with stabilized ceramic beads. RNase free.

YELLOW RINO RNA Lysis Kit 250

YELLOWR5-RNA 250pack
EUR 656
Description: Bead lysis kits for the homogenization of small cell suspensions (ex - E. coli). Pack of 250, 1.5mL RINO screw-cap tubes prefilled with stabilized ceramic beads. RNase free.

Coronavirus (SARS-Cov-2) Antigen Rapid Test Device (Saliva)

IOV87952 20T/kit
EUR 39
Description: Coronavirus (SARS-Cov-2) Antigen Rapid Test Device (Saliva) is an in vitro diagnostic test for the qualitative detection of novel coronavirus antigens in human saliva, using the rapid immunochromatographic method. The identification is based on the monoclonal antibodies specific for the novel coronvirus antigen. It will provide information for clinical doctors to prescribe correct medications.

Anti-SARS-CoV-2 Neutralization Antibody Test Kit (Colloidal gold immunoassay)

CP04010 25T/kit Ask for price
Description: The Anti-SARS-CoV-2 Neutralization Antibody Test Kit (Serum/Plasma/Whole blood) is a qualitative membrane-based immunoassay for the detection of SARS-CoV-2 neutralizing antibodies in serum, plasma and whole blood. The sample is dropped into the sample well, and chromatography is performed under the capillary effect. The SARS-CoV-2 neutralizing antibodies in the sample combined with the colloidal gold-labeled SARS-CoV-2 spike protein(SP), then spread to the test area. It is captured by coated SP subunit RBDNTD-CTD, to form a complex and gather in the test area (T line). The quality control area is coated with mouse anti-chicken IgY, and the colloidal goldlabeled chicken IgY is captureed to form a complex and aggregate in hte quality control area (C line). If the C line does not show color, it indicates that the result is invalid, and this sample need to be tested again.

Anti-SARS-CoV-2 Neutralization Antibody Test Kit (Enzyme-linked immunosorbent assay)

CP04012 96T/5*96T Ask for price
Description: It is a semi quantitative competition ELISA kit to detect the Anti-SARS-CoV-2 Neutralization Antibody in human serum or plasma. The micro test plate provided in this kit is pre-coated with recombinant human ACE2. During the reaction, the SARS-CoV-2 neutralization antibody in the standard & sample diluent pretreated samples or controls competes with a fixed amount of human ACE2 on the solid phase supporter for sites on the Horseradish peroxidase (HRP) conjugated recombinant SARS-CoV-2 RBD fragment (HRP-RBD). After 37℃incubation, the unbound HRP-RBD as well as any HRP-RBD bound to non-neutralization antibody will be captured on the plate and eventually form the ACE2-RBD-HRP complex, while the circulating neutralization antibodies HRP-RBD complexes remain in the supernatant and are removed during washing. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm.